| Curriculum |
|
|
|
| Schedule |
Subjects |
Contents |
|
| 1st day |
Causes of insulation aging |
Learn about structures of motor insulation systems, insulation classes, causes of insulation aging, and types of aging. |
|
| Methodology of insulation diagnosis testing |
Learn about testing methods and principles as well as assessment methods of DC absorption test, dielectric loss tangent test, AC voltage/current test, and partial discharge test. |
|
| Insulation diagnosis testing亂Practical training亃 |
Conduct DC absorption test of 3.3kV motor to promote understanding of testing methodology and acquire expertise of safety and quality management for testing. |
|
| 2nd day |
Insulation diagnosis testing亂Practical training亃 |
Conduct dielectric loss tangent test, AC voltage/current test and partial discharge test of 3.3kV motor to promote understanding of testing methodology and acquire expertise of safety and quality management for testing. |
|
| Technologies for assessing insulation testing results |
Learn about assessment technologies, technologies for analyzing deteriorated parts, conceptions of remaining life diagnosis through analyzing practical testing data. |
|
| Preventive maintenance |
Learn about technologies and methods of preventive maintenance for motor. |
|